Video for DCIT Weld Gun Station performing
single trigger welds using RAFT
Testing the Adaptive Performance - Five Different Stacks
Stack No 1: (B1.0B x B1.0B)
Welding of this nugget was performed in 191mS with an
average current of 11923A. The observed Resistance Drop
measured 41.0%. This is close to the reference setup of
179mS with a current regulation schedule of 12000A.
Stack No 2: (G1.2G x G1.2G)
Welding of this nugget was performed in 316mS with an
average current of 13124A. The observed Resistance Drop
measured 31.9%.
Stack No 3:(G1.5G x G0.8G x
G1.5G) Welding of this nugget was performed in 303mS
with an average current of 11791A. The observed
Resistance Drop measured 38.2%
Stack No 4: (G0.8G
x G1.5G x G1.5G) Welding of this nugget was performed in
510mS with an average current of 11659A. The observed
Resistance Drop measured 30.9%.
Stack No 5: (G0.8G x B0.7B x
G1.5G) Welding of this nugget was performed in 310mS
with an average current of 12084A. The observed
Resistance Drop measured 38.7%.