Pre-requisite: Voltage Input at CPU must be terminated correctly

This graph shows both the results of a proper and inproper termination of the voltage input as the RAFT CPU. When doing a resistance offset measure, the results will show on the RAFT gateway screen.

A resistance measure was done here by firing 8000 amperes for 230 milliseconds. When the voltage inputs are correctly terminated, the resistance will show a steady value that can range from 30 to 150 micro-Ohms.

When the voltage inputs are incorrectly terminated, the resistance will be off the chart and will register 1000 micro-Ohms of resistance.

To Top