Pre-requisite: Voltage Input at CPU must be terminated correctly
This graph shows both the results of a proper and
inproper termination of the voltage input as the RAFT
CPU. When doing a resistance offset measure, the results
will show on the RAFT gateway screen.
A resistance measure was done here by firing 8000
amperes for 230 milliseconds. When the voltage inputs
are correctly terminated, the resistance will show a
steady value that can range from 30 to 150 micro-Ohms.
When the voltage inputs are incorrectly terminated, the
resistance will be off the chart and will register 1000
micro-Ohms of resistance.