Pre-requisite: Reference welds must not be expulsion welds
A good reference weld will have a classic dynamic resistance curve that is free of expulsion. Welds with expulsion will show a large sudden decrease in resistance. The graph to the right shows the detection of expulsion at 265th millisecond into the weld.