Pre-requisite: Mounting points on the welding gun
Place the wires near the water ports located on the welding gun arms. This area is ideal
since it is unlikely to get damaged over time and the resistance will be constant.
The secondary voltage tip wires are required to be installed before the cap adapter and after
the leaf shunts. The leaf shunts will break over time changing their resistance which will
adversely effect the welding process.